Problem converting from .odt to .epub

Bug #1898441 reported by pascal
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
calibre
Fix Released
Undecided
Unassigned

Bug Description

Converting from .odt to .epub fail on Calibre 5.1 and Calibre 5.01 (Windows 10)
Conversion is OK on Calibre 4.23

calibre, version 5.1.0 (win32, embedded-python: True)
Erreur lors de la conversion: Échoué: Conversion du livre 1 sur 1 (Copie Corps et armes)

Conversion du livre 1 sur 1 (Copie Corps et armes)
Conversion options changed from defaults:
  read_metadata_from_opf: 'C:\\Users\\Pascal\\AppData\\Local\\Temp\\calibre_guowvk8c\\7jlf5gn4.opf'
  verbose: 2
Resolved conversion options
calibre version: 5.1.0
{'asciiize': False,
 'author_sort': None,
 'authors': None,
 'base_font_size': 0.0,
 'book_producer': None,
 'change_justification': 'original',
 'chapter': "//*[((name()='h1' or name()='h2') and re:test(., "
            "'\\s*((chapter|book|section|part)\\s+)|((prolog|prologue|epilogue)(\\s+|$))', "
            "'i')) or @class = 'chapter']",
 'chapter_mark': 'pagebreak',
 'comments': None,
 'cover': None,
 'debug_pipeline': None,
 'dehyphenate': True,
 'delete_blank_paragraphs': True,
 'disable_font_rescaling': False,
 'dont_split_on_page_breaks': False,
 'duplicate_links_in_toc': False,
 'embed_all_fonts': False,
 'embed_font_family': None,
 'enable_heuristics': False,
 'epub_flatten': False,
 'epub_inline_toc': False,
 'epub_toc_at_end': False,
 'epub_version': '2',
 'expand_css': False,
 'extra_css': None,
 'extract_to': None,
 'filter_css': '',
 'fix_indents': True,
 'flow_size': 260,
 'font_size_mapping': None,
 'format_scene_breaks': True,
 'html_unwrap_factor': 0.4,
 'input_encoding': None,
 'input_profile': <calibre.customize.profiles.InputProfile object at 0x000001C3ED5F6B80>,
 'insert_blank_line': False,
 'insert_blank_line_size': 0.5,
 'insert_metadata': False,
 'isbn': None,
 'italicize_common_cases': True,
 'keep_ligatures': False,
 'language': None,
 'level1_toc': None,
 'level2_toc': None,
 'level3_toc': None,
 'line_height': 0.0,
 'linearize_tables': False,
 'margin_bottom': 5.0,
 'margin_left': 5.0,
 'margin_right': 5.0,
 'margin_top': 5.0,
 'markup_chapter_headings': True,
 'max_toc_links': 50,
 'minimum_line_height': 120.0,
 'no_chapters_in_toc': False,
 'no_default_epub_cover': False,
 'no_inline_navbars': False,
 'no_svg_cover': False,
 'output_profile': <calibre.customize.profiles.OutputProfile object at 0x000001C3ED5F6E50>,
 'page_breaks_before': "//*[name()='h1' or name()='h2']",
 'prefer_metadata_cover': False,
 'preserve_cover_aspect_ratio': False,
 'pretty_print': True,
 'pubdate': None,
 'publisher': None,
 'rating': None,
 'read_metadata_from_opf': 'C:\\Users\\Pascal\\AppData\\Local\\Temp\\calibre_guowvk8c\\7jlf5gn4.opf',
 'remove_fake_margins': True,
 'remove_first_image': False,
 'remove_paragraph_spacing': False,
 'remove_paragraph_spacing_indent_size': 1.5,
 'renumber_headings': True,
 'replace_scene_breaks': '',
 'search_replace': '[]',
 'series': None,
 'series_index': None,
 'smarten_punctuation': False,
 'sr1_replace': None,
 'sr1_search': None,
 'sr2_replace': None,
 'sr2_search': None,
 'sr3_replace': None,
 'sr3_search': None,
 'start_reading_at': None,
 'subset_embedded_fonts': False,
 'tags': None,
 'timestamp': None,
 'title': None,
 'title_sort': None,
 'toc_filter': None,
 'toc_threshold': 6,
 'toc_title': None,
 'transform_css_rules': '[]',
 'unsmarten_punctuation': False,
 'unwrap_lines': True,
 'use_auto_toc': False,
 'verbose': 2}
InputFormatPlugin: ODT Input running
on C:\Users\Pascal\AppData\Local\Temp\calibre_guowvk8c\p284essh.odt
Extracting ODT file...
Traceback (most recent call last):
  File "runpy.py", line 194, in _run_module_as_main
  File "runpy.py", line 87, in _run_code
  File "site.py", line 89, in <module>
  File "site.py", line 84, in main
  File "site.py", line 55, in run_entry_point
  File "site-packages\calibre\utils\ipc\worker.py", line 215, in main
  File "site-packages\calibre\gui2\convert\gui_conversion.py", line 41, in gui_convert_override
  File "site-packages\calibre\gui2\convert\gui_conversion.py", line 28, in gui_convert
  File "site-packages\calibre\ebooks\conversion\plumber.py", line 1108, in run
  File "site-packages\calibre\customize\conversion.py", line 245, in __call__
  File "site-packages\calibre\ebooks\conversion\plugins\odt_input.py", line 25, in convert
  File "site-packages\calibre\ebooks\odt\input.py", line 283, in __call__
  File "site-packages\odf\odf2xhtml.py", line 1613, in xhtml
TypeError: sequence item 11414: expected str instance, bytes found

Revision history for this message
pascal (pascal-deville) wrote :
Revision history for this message
Kovid Goyal (kovid) wrote : Fixed in master

Fixed in branch master. The fix will be in the next release. calibre is usually released every alternate Friday.

 status fixreleased

Changed in calibre:
status: New → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.