the munin plugin sensors_ does not recognize the values of volt and fan from lm-sensors
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
munin (Ubuntu) |
New
|
Low
|
Unassigned |
Bug Description
the plugin shows only the temperatures and does not recognize the other values
#console output of the plugin and lmsensors
root@server:~# /etc/munin/
temp
root@server:~# /etc/munin/
root@server:~# /etc/munin/
root@server:~# /etc/munin/
temp1.value 30.0
temp2.value 20.0
temp3.value 33.0
temp4.value 22.0
temp5.value 18.0
temp6.value 25.0
root@server:~#
root@server:~#
root@server:~#
root@server:~# sensors
k8temp-pci-00c3
Adapter: PCI adapter
Core0 Temp: +32.0°C
Core0 Temp: +23.0°C
Core1 Temp: +35.0°C
Core1 Temp: +26.0°C
f71882fg-isa-0a00
Adapter: ISA adapter
+3.3V: +3.39 V
in1: +1.11 V (max = +2.04 V)
in2: +1.12 V
in3: +0.95 V
in4: +0.65 V
in5: +1.10 V
in6: +0.78 V
3VSB: +3.39 V
Vbat: +3.17 V
fan1: 1400 RPM
fan2: 825 RPM
fan3: 1107 RPM
fan4: 0 RPM ALARM
temp1: +19.0°C (high = +85.0°C, hyst = +81.0°C)
temp2: +25.0°C (high = +85.0°C, hyst = +81.0°C)
temp3: FAULT (high = +70.0°C, hyst = +68.0°C)
ProblemType: Bug
DistroRelease: Ubuntu 10.04
Package: munin 1.4.4-1ubuntu1
ProcVersionSign
Uname: Linux 2.6.32-34-generic x86_64
NonfreeKernelMo
Architecture: amd64
Date: Thu Sep 29 22:00:22 2011
PackageArchitec
ProcEnviron:
PATH=(custom, no user)
LANG=de_DE.UTF-8
SHELL=/bin/bash
SourcePackage: munin
Changed in munin (Ubuntu): | |
importance: | Undecided → Low |