Traffic to floating IP does not work from network worker

Bug #716414 reported by Soren Hansen
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
OpenStack Compute (nova)
Fix Released
Undecided
Soren Hansen

Bug Description

From the network node, you cannot reach instances on their floating IP, because the DNAT rule is only in PREROUTING. Since the destination address is local (having been added to FLAGS.public_interface) this rule is not applied and the request instead ends up on the host.

Related branches

Revision history for this message
Soren Hansen (soren) wrote :

This may sound pointless (why would anyone be initiating connections from the network node), by the way, but it comes in very handy during testing.

Changed in nova:
assignee: nobody → Soren Hansen (soren)
Changed in nova:
status: New → Fix Committed
Thierry Carrez (ttx)
Changed in nova:
milestone: none → 2011.2
status: Fix Committed → Fix Released