Import Schematic, fp update with element on far side Fails
Bug #699331 reported by
fdelapuente
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
pcb |
Fix Released
|
Medium
|
Unassigned |
Bug Description
When you "Import Schematics" on an existing layout and elements on the far side are being updated(footprint attribute changed...), the newly inserted footprint is wrong in the following two aspects:
1. It's Positioned on "Current View Side"(good coordinates, but wrong side)
2. It's Vertically mirrored.
This is git version of pcb, up to date(201010).
Changed in pcb: | |
milestone: | future-bug-release → next-bug-release |
Changed in pcb: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
Bug was fixed by a commit 406522bfce59c63 e5518f4cfa git.gpleda. org/?p= pcb.git; a=commit; h=c4df558415e97 7e406522bfce59c 63e5518f4cfa
git master commit c4df558415e977e
http://
commit c4df558415e977e 406522bfce59c63 e5518f4cfa
Author: DJ Delorie <email address hidden>
Commit: DJ Delorie <email address hidden>
Fix File->Import for elements on back side.
Mirror pasted footprints when replacing back-side elements. Also
clear element cache when reloading the new footprint, to avoid getting a
stale pointer.
Closes-bug: lp-699331