portable server library intermittent failure

Bug #541125 reported by Jeff Hill
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
EPICS Base
Fix Released
High
Jeff Hill

Bug Description

Failure occurring if client disconnects while asynchronous PV attach is outstanding, or, for enumerated native type process variables, while enumerated string table cache asynchronous IO is outstanding. This problem does not occur in IOCs because they are not yet based on the portable server library.

Additional information:
The bug was first detected by Ken Evans in the CA gateway when the problem was occurring infrequently in the production gatweway at the APS.

Original Mantis Bug: mantis-45
    http://www.aps.anl.gov/epics/mantis/view_bug_page.php?f_id=45

Tags: 3.14
Revision history for this message
Jeff Hill (johill-lanl) wrote :

Fix applied to CVS. Release is pending production testing in the CA gateway at the APS.

Revision history for this message
Andrew Johnson (anj) wrote :

R3.14.5 released.

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches