while log in, the message "One or more disks are failing" apears, but RAID1 disks seem to be OK
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
gnome-disk-utility (Ubuntu) |
Confirmed
|
Undecided
|
Unassigned |
Bug Description
Binary package hint: gnome-disk-utility
I am using mdadm RAID1 created during the instalation using alternate CD.
After log in, the window with the message "One or more disks are failing" appears, the session starts properly, but there is small disk icon in the Notification Area (see attached screenshot).
When click on the name of the disk, the Palimpsest application starts and all disks are without errors. When closed, the disk icon stays in the Notification Area.
devkit-disks --show-info /dev/sda
devkit-disks --show-info /dev/sdb
are returning "bad sectors: Yes" (see bellow)
the same command for the /dev/md0, /dev/md1, /dev/sda1, /dev/sda5, /dev/sdb1, /dev/sdb5
does not return any error.
I have found similar symptoms/problem described in the bug 421263 ( https:/
=======
root@korzar-
Showing information for /org/freedeskto
native-path: /sys/devices/
device: 8:16
device-file: /dev/sdb
by-id: /dev/disk/
by-id: /dev/disk/
by-path: /dev/disk/
detected at: Ne 6. září 2009, 10:07:06 CEST
system internal: 1
removable: 0
has media: 1 (detected at Ne 6. září 2009, 10:07:06 CEST)
detects change: 0
detection by polling: 0
detection inhibitable: 0
detection inhibited: 0
is read only: 0
is mounted: 0
mount paths:
mounted by uid: 0
presentation hide: 0
presentation nopolicy: 0
presentation name:
presentation icon:
size: 74355769344
block size: 512
job underway: no
usage:
type:
version:
uuid:
label:
partition table:
scheme: mbr
count: 3
drive:
vendor: ATA
model: WDC WD740GD-00FLA0
revision: 21.08U21
serial: WD-WMAKE1097108
detachable: 0
can spindown: 1
rotational media: 1
ejectable: 0
media:
compat:
interface: ata
if speed: (unknown)
ATA SMART: Updated at Ne 6. září 2009, 17:37:07 CEST
assessment: Unknown
bad sectors: Yes
attributes: Within threshold
temperature: 41° C / 106° F
powered on: 1,47e+03 days
offline data: suspended (2385 second(s) to complete)
self-test status: success or never (0% remaining)
ext./short test: available
conveyance test: available
start test: available
abort test: available
short test: 2 minute(s) recommended polling time
ext. test: 37 minute(s) recommended polling time
conveyance test: 5 minute(s) recommended polling time
=======
Attribute Current/
=======
raw-read-
spin-up-time 72/ 67/ 21 good 4,9 secs Prefail Online
start-stop-count 100/100/ 40 good 532 Old-age Online
reallocated-
seek-error-rate 100/253/ 51 good 0 Prefail Online
power-on-hours 52/ 52/ 0 n/a 1,47e+03 days Old-age Online
spin-retry-count 100/100/ 51 good 0 Prefail Online
calibration-
power-cycle-count 100/100/ 0 n/a 481 Old-age Online
temperature-
reallocated-
current-
offline-
udma-crc-
multi-
ProblemType: Bug
Architecture: amd64
Date: Sun Sep 6 17:45:05 2009
DistroRelease: Ubuntu 9.10
NonfreeKernelMo
Package: gnome-disk-utility 0.5-0ubuntu3
ProcEnviron:
LANG=cs_CZ.UTF-8
SHELL=/bin/bash
ProcVersionSign
SourcePackage: gnome-disk-utility
Uname: Linux 2.6.31-9-generic x86_64
same problem here.
After i upgraded to karmic i instantly got this message. The disc is only 22.3 days powered on.