computer_power_supply_ac_adapter_C171 property ac_adapter.present" keeps on changing between TRUE and FALS E about every second

Bug #330693 reported by Peter
2
Affects Status Importance Assigned to Milestone
hal (Ubuntu)
Invalid
Undecided
Unassigned

Bug Description

Binary package hint: hal

[Ubuntu 8.10]; [hal: Installed: 0.5.11-4ubuntu4; Candidate: 0.5.11-4ubuntu4; Version table: *** 0.5.11-4ubuntu4 0; 500 http://ch.archive.ubuntu.com intrepid/main Packages;100 /var/lib/dpkg/status]

My notebook only works on ac when the battery is fully charged... so far okay; if the battery is -not- charged (< 100%) the status of the "computer_power_supply_ac_adapter_C171 property ac_adapter.present" keeps on changing between TRUE and FALSE every second and, due to this change of status, the battery does not charge; charging is only possible when the computer turned off.

(a) lshal -m with battery 100% charged

Start monitoring devicelist:
-------------------------------------------------
===> unplugging the ac.adapter
20:06:04.652: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:06:04.850: computer property power_management.is_powersave_set = true
20:06:04.913: computer_power_supply_battery_C173 property battery.remaining_time = 2648 (0xa58) (new)
20:06:04.917: computer_power_supply_battery_C173 property battery.charge_level.rate = 38295 (0x9597)
20:06:04.919: computer_power_supply_battery_C173 property battery.rechargeable.is_discharging = true
20:06:04.920: computer_power_supply_battery_C173 property battery.reporting.rate = 3450 (0xd7a)
20:06:04.923: computer_power_supply_battery_C173 property battery.voltage.current = 12248 (0x2fd8)
===> ac.adapter plugged in
20:06:09.712: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:06:09.910: computer property power_management.is_powersave_set = false
20:06:12.032: computer_power_supply_battery_C173 property battery.remaining_time removed
20:06:12.032: computer_power_supply_battery_C173 property battery.charge_level.rate = 0 (0x0)
20:06:12.036: computer_power_supply_battery_C173 property battery.charge_level.current = 28149 (0x6df5)
20:06:12.039: computer_power_supply_battery_C173 property battery.reporting.current = 2536 (0x9e8)
20:06:12.040: computer_power_supply_battery_C173 property battery.rechargeable.is_discharging = false
20:06:12.042: computer_power_supply_battery_C173 property battery.reporting.rate = 0 (0x0)
20:06:12.044: computer_power_supply_battery_C173 property battery.voltage.current = 12223 (0x2fbf)

(b) lshal -m with battery 92 % charged; ac.adapter plugged in
Start monitoring devicelist:
-------------------------------------------------
20:36:43.494: computer property power_management.is_powersave_set = false
20:36:43.935: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:36:44.124: computer property power_management.is_powersave_set = true
20:36:44.190: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:36:45.998: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:36:46.436: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:36:46.639: computer property power_management.is_powersave_set = false
20:36:47.950: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:36:48.148: computer property power_management.is_powersave_set = true
20:36:48.545: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:36:48.759: computer property power_management.is_powersave_set = false
20:36:50.010: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:36:50.198: computer property power_management.is_powersave_set = true
20:36:50.287: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:36:52.069: computer_power_supply_ac_adapter_C171 property ac_adapter.present = false
20:36:52.460: computer_power_supply_ac_adapter_C171 property ac_adapter.present = true
20:36:52.669: computer property power_management.is_powersave_set = false

Revision history for this message
dino99 (9d9) wrote :
Changed in hal (Ubuntu):
status: New → Invalid
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.