Add heartbeat_timeout to juju configuration

Bug #2000420 reported by Alan Baghumian
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
OpenStack Octavia Charm
In Progress
Wishlist
Neil Campbell

Bug Description

Hello There,

There are occasions where we need to adjust the heartbeat_timeout default, which is 60 seconds, to avoid unnecessary amphora failover actions.

Currently we can manually add this line under the [health_manager] section of /etc/octavia/octavia.conf on all units, however the issue is they would get removed upon reboots:

[health_manager]
heartbeat_timeout = 120

It would be nice to have this as a configuration option with the charm.

Please let me know if you have any questions.

Thank you,
Alan

Revision history for this message
Alex Kavanagh (ajkavanagh) wrote :

This would be useful and relatively easy to add.

Changed in charm-octavia:
importance: Undecided → Wishlist
status: New → Triaged
tags: added: good-first-bug
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to charm-octavia (master)
Changed in charm-octavia:
status: Triaged → In Progress
Changed in charm-octavia:
assignee: nobody → Neil Campbell (neil-campbell)