suppressing script results no longer available on machine listing

Bug #1995624 reported by Peter Makowski
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
MAAS
Fix Released
High
Alexsander de Souza

Bug Description

It is no longer possible to suppress script results on machine listing page and only works on machine details in 3.3.0.

This be added back to the UI once the following back-end changes are implemented:

- machine.set_script_result_suppressed needs to accept the filter param in order for the action to work with server-side machine listing.
- (this could be optional) noderesult.list needs to accept the filter param in order for the UI to be able to display a count of machines with failed tests.

Related branches

Changed in maas:
status: New → Triaged
importance: Undecided → High
Revision history for this message
Anton Troyanov (troyanov) wrote :

Setting it to High, because we are breaking functionality that used to work in 3.2.x

Changed in maas:
milestone: none → 3.3.0
tags: added: bug-council
Changed in maas:
assignee: nobody → Alexsander de Souza (alexsander-souza)
tags: removed: bug-council
Changed in maas:
status: Triaged → In Progress
Changed in maas:
status: In Progress → Fix Committed
Changed in maas:
milestone: 3.3.0 → 3.3.0-beta3
status: Fix Committed → Fix Released