Bug Description
[Impact]
Intel TGP dekstop cannot detect second monitor.
[Fix]
Remove an IRQ setup routine and re-order some other IRQ setups.
[Test]
1. Boot up the system with single monitor connected.
2. Hotplug second monitor.
With the fix applied, the system can detect the 2nd monitor correctly.
[Where problems could occur]
This fix removed some special handling for early gen Core, so HPD on
those old Core systems might be affected.
Changed in linux-oem-5.10 (Ubuntu): | |
status: | New → Invalid |
Changed in linux-oem-5.10 (Ubuntu Focal): | |
status: | New → Confirmed |
importance: | Undecided → Medium |
tags: | added: oem-priority originate-from-1933585 stella |
Changed in linux-oem-5.10 (Ubuntu Focal): | |
status: | Confirmed → Fix Committed |
Changed in hwe-next: | |
status: | New → Fix Released |
To post a comment you must log in.
This bug is awaiting verification that the kernel in -proposed solves the problem. Please test the kernel and update this bug with the results. If the problem is solved, change the tag 'verification- needed- focal' to 'verification- done-focal' . If the problem still exists, change the tag 'verification- needed- focal' to 'verification- failed- focal'.
If verification is not done by 5 working days from today, this fix will be dropped from the source code, and this bug will be closed.
See https:/ /wiki.ubuntu. com/Testing/ EnableProposed for documentation how to enable and use -proposed. Thank you!