[Reproduce Steps]
1. Flash Latest BIOS 0.1.7, Install Ubuntu OS 20.04.1.
2. Connect DP and HDMI monitor to WD19 SC dock,then plug dock to SUT.
3. Then unplug WD19 SC dock,find SUT hang about 6s.--->Problem(refer to video)

[Result]
Expected Result
 SUT not should hang about 6s after unplug salomon dock with connect DP and HDMI monitor
Actual Result
 SUT hang about 6s after unplug salomon dock with connect DP and HDMI monitor.

[Additional Information]
1. Test Vault ID: 60773.011
2. SKU: CBL TGL SKU7
3. CPU: I5-1135G7
4. GPU: NVIDIA MX450(N18S-G5-A1)
5. BIOS Version: 0.1.9
6. Image/Manifest: Ubuntu 20.04.1 LTS (fossa X51)
7. Kernel Version:5.6.0-1036-oem
8. Salomon SC dock:dock-312(FW:1.0.15 DP/N 01887B)
9. Monitor: DP monitor(Monitor-98;P3418HW; Monitor-133; P2018)

NOtes:
1. VNP on only connect one DP/HDMI monitor

Failure rate: 100%

lo (jasonlo)
Changed in synctooltest:
status: Triaged → New
Revision history for this message
OEM Taipei Bot (oem-taipei-bot) wrote :

[Automated ODM-sync-tool comment]
This bug has been synced to somerville Launchpad project successfully.
Please refer to Bug #1917571

tags: added: synctooltest
Changed in synctooltest:
assignee: nobody → StanleyHuang (stanley31)
importance: High → Undecided
Revision history for this message
lo (jasonlo) wrote :
Changed in synctooltest:
status: New → Triaged
Changed in synctooltest:
assignee: StanleyHuang (stanley31) → lo (jasonlo)