SIP crash with metarecord holds and msg64_hold_datatype = barcode
Bug #1843466 reported by
Jeff Godin
This bug affects 10 people
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Evergreen |
Confirmed
|
Undecided
|
Jeff Godin |
Bug Description
The SIP code will crash when generating a patron information response when msg64_datatype is set to barcode and the SIP client requests hold items.
The server does not send a response, and the end user symptoms may vary by client.
SIP error log may contain:
No field by the name record in Fieldmapper:
The field we're looking for is "source", not "record".
Branch forthcoming.
To post a comment you must log in.
I have tested this on Evergreen 3.3 and 3.6. and ran into the same issue. I can also confirm that the this is an issue for parts holds as well as metarecord holds.