I have a number of schematics in which is is not visually feasible for no-connects to be directly placed at the associated connector pins, and therefore in those cases there is a short wire between the pin and the no-connect.
This has always been accepted by ERC before, but with the latest nightly build it is flagged as an error. (So I can have dozens of these errors on any given schematic.)
Perhaps this is related to the recent fix for bug #1821342, which also involved wires between component pins and no-connects.
Application: kicad
Version: 5.1.0-unknown-
Libraries:
wxWidgets 3.0.2
libcurl/7.47.0 OpenSSL/1.0.2g zlib/1.2.11 libidn/1.32 librtmp/2.3
Platform: Linux 4.4.0-53-generic x86_64, 64 bit, Little endian, wxGTK
Build Info:
wxWidgets: 3.0.2 (wchar_t,wx containers,
Boost: 1.58.0
OpenCASCADE Community Edition: 6.8.0
Curl: 7.47.0
Compiler: GCC 5.4.0 with C++ ABI 1009
Build settings:
USE_
USE_
KICAD_
KICAD_
KICAD_
KICAD_
KICAD_
KICAD_
BUILD_
KICAD_
KICAD_
KICAD_SPICE=ON
Changed in kicad: | |
assignee: | nobody → Jon Evans (craftyjon) |
importance: | Undecided → Low |
milestone: | none → 6.0.0-rc1 |
Fixed in revision df600fc1a2f55c0 32e02c41fbdf1b2 db412954cc /git.launchpad. net/kicad/ patch/? id=df600fc1a2f5 5c032e02c41fbdf 1b2db412954cc