There is no option to set physical_network_mtus via heat template

Bug #1782123 reported by Kamil Sambor
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
tripleo
Fix Released
Medium
Kamil Sambor

Bug Description

In OSP there is an option to set different MTU value for each physnet.
We need to have an option to set it as a part of OSPD and add this parameter to heat template.

Kamil Sambor (ksambor)
Changed in tripleo:
assignee: nobody → Kamil Sambor (ksambor)
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (master)

Fix proposed to branch: master
Review: https://review.openstack.org/583211

Changed in tripleo:
status: New → In Progress
Changed in tripleo:
milestone: none → rocky-3
importance: Undecided → Medium
Changed in tripleo:
milestone: rocky-3 → rocky-rc1
Changed in tripleo:
milestone: rocky-rc1 → stein-1
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (master)

Reviewed: https://review.openstack.org/583211
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=29bd1a9d87f44eb1cbefafe72a2a5688d5fc609d
Submitter: Zuul
Branch: master

commit 29bd1a9d87f44eb1cbefafe72a2a5688d5fc609d
Author: Kamil Sambor <email address hidden>
Date: Tue Jul 17 13:27:10 2018 +0200

    Allow setting physical network MTU via heat template

    Add 'neutron::plugins::ml2::physical_network_mtus' as a
    NeutronML2PhysicalNetworkMtus in heat template to allow
    set MTU in ml2 plugin

    Change-Id: I2f9666a5422a1272d53c869e4dad8581ab605b37
    Closes-Bug: 1782123

Changed in tripleo:
status: In Progress → Fix Released
Changed in tripleo:
milestone: stein-1 → rocky-rc1
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 9.0.0.0rc1

This issue was fixed in the openstack/tripleo-heat-templates 9.0.0.0rc1 release candidate.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (stable/queens)

Fix proposed to branch: stable/queens
Review: https://review.openstack.org/611794

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (stable/queens)

Reviewed: https://review.openstack.org/611794
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=f19a45bd9d915bd3fe80aa34bf93528ad74bedba
Submitter: Zuul
Branch: stable/queens

commit f19a45bd9d915bd3fe80aa34bf93528ad74bedba
Author: Kamil Sambor <email address hidden>
Date: Tue Jul 17 13:27:10 2018 +0200

    Allow setting physical network MTU via heat template

    Add 'neutron::plugins::ml2::physical_network_mtus' as a
    NeutronML2PhysicalNetworkMtus in heat template to allow
    set MTU in ml2 plugin

    Change-Id: I2f9666a5422a1272d53c869e4dad8581ab605b37
    Closes-Bug: 1782123
    (cherry picked from commit 29bd1a9d87f44eb1cbefafe72a2a5688d5fc609d)

tags: added: in-stable-queens
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 8.1.0

This issue was fixed in the openstack/tripleo-heat-templates 8.1.0 release.