Ignore unconnected pins option in ERC.
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Expired
|
Wishlist
|
Bug Description
I was trying to do some ERC on a partially completed schematic, and got hundreds of "No-connection" warnings. As I am not yet done the schematic, I figured I'd just turn those off so I could see if everything else is okay.
After turning all of the warnings off in the ERC options (all buttons on bottom row clicked to green), I run ERC again, and still get warnings on every non-connected pin.
Screenshot is here:
https:/
Application: kicad
Version: 5.0.0-rc2-
Libraries:
wxWidgets 3.0.3
libcurl/7.55.1 OpenSSL/1.0.2g zlib/1.2.11 libidn2/2.0.2 libpsl/0.18.0 (+libidn2/2.0.2) librtmp/2.3
Platform: Linux 4.13.0-32-generic x86_64, 64 bit, Little endian, wxGTK
Build Info:
wxWidgets: 3.0.3 (wchar_t,wx containers,
Boost: 1.62.0
Curl: 7.55.1
Compiler: GCC 7.2.0 with C++ ABI 1011
Build settings:
USE_
USE_
KICAD_
KICAD_
KICAD_
KICAD_
BUILD_
KICAD_
KICAD_SPICE=ON
This bug also occurs in 4.0.6 according to bobc on the kicad.info forums (In the thread with the screenshot, linked above)
Changed in kicad: | |
importance: | Undecided → Wishlist |
status: | New → Triaged |
summary: |
- No connection warnings are tagged, even if disabled in ERC options. + Ignore unconnected pins option in ERC. |
Changed in kicad: | |
assignee: | nobody → Jon Evans (craftyjon) |
Changed in kicad: | |
milestone: | none → 6.0.0-rc1 |
tags: | added: eeschema erc |
"No Connect" in the pin table means that the pin type is set to "No Connect" not that there is no connection to the pin itself. Your change to the pin table will allow you to connect two "No Connect" pins together without an error. My guess that you want an optional "Ignore unconnected pins" option which we currently do no support.