It is impossible to reset a TCS emergency in explorer mode

Bug #1680533 reported by Carlo Santucci
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Open Rails
Fix Released
Medium
Carlo Santucci

Bug Description

It is impossible to reset a TCS emergency in explorer mode. TCS emergency in explorer mode can especially occur when playing multiplayer.
In auto mode the reset is accomplished by passing in manual mode pressing CTRL+M. This does not work up to now from explorer mode because passing in manual mode is denied in this case.
The implemented patch allows resetting TCS emergency in explorer mode the same way as in auto mode, that is pressing CTRL+M. The TCS emergency is reset this way, but the train remains in explorer mode.

Tags: physics
Revision history for this message
Carlo Santucci (carlosanit1) wrote :

Fixed in x.3823.

Changed in or:
status: New → In Progress
assignee: nobody → Carlo Santucci (carlosanit1)
description: updated
description: updated
Changed in or:
status: In Progress → Fix Committed
James Ross (twpol)
Changed in or:
milestone: none → 1.3
importance: Undecided → Medium
James Ross (twpol)
Changed in or:
status: Fix Committed → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.