ceilometer-compute-agent failed to collect metrics after rebooting a compute host

Bug #1649921 reported by Mehdi Abaakouk
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Ceilometer
Fix Released
Medium
Mehdi Abaakouk

Bug Description

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to ceilometer (stable/newton)

Fix proposed to branch: stable/newton
Review: https://review.openstack.org/410808

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to ceilometer (stable/mitaka)

Fix proposed to branch: stable/mitaka
Review: https://review.openstack.org/410809

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to ceilometer (stable/newton)

Reviewed: https://review.openstack.org/410808
Committed: https://git.openstack.org/cgit/openstack/ceilometer/commit/?id=d84b976c85252c2daa29a2bcaaba7266330abcb3
Submitter: Jenkins
Branch: stable/newton

commit d84b976c85252c2daa29a2bcaaba7266330abcb3
Author: Mehdi Abaakouk <email address hidden>
Date: Mon Nov 28 13:14:54 2016 +0100

    Revert "Add hypervisor inspector sanity check"

    This change have introduced an issue, when the libvirt unix socket
    is created after Ceilometer start. The pollster is disabled when
    it should wait that libvirt come up.

    The intent of the original bug was only to have a cosmetic logs
    when the configuration file is wrong.

    Also I don't see a safe way to disable the pollster when we can't
    connect to libvirt, the reason is always unknown from Ceilometer PoV.

    This reverts commit d17e75d2675c1acf09adc27249b1e968450c5229.

    Closes-bug: #1649921
    Change-Id: I63479d19fcf4a99fb198859c2e6ae370ff0e24e1
    (cherry picked from commit 72b5a1e2bc9f4fc3f551a41aa0e40cd59f8ab5c9)

tags: added: in-stable-newton
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to ceilometer (stable/mitaka)

Reviewed: https://review.openstack.org/410809
Committed: https://git.openstack.org/cgit/openstack/ceilometer/commit/?id=1c5ad24f221f90310577b1de29acdd4f496ea705
Submitter: Jenkins
Branch: stable/mitaka

commit 1c5ad24f221f90310577b1de29acdd4f496ea705
Author: Mehdi Abaakouk <email address hidden>
Date: Mon Nov 28 13:14:54 2016 +0100

    Revert "Add hypervisor inspector sanity check"

    This change have introduced an issue, when the libvirt unix socket
    is created after Ceilometer start. The pollster is disabled when
    it should wait that libvirt come up.

    The intent of the original bug was only to have a cosmetic logs
    when the configuration file is wrong.

    Also I don't see a safe way to disable the pollster when we can't
    connect to libvirt, the reason is always unknown from Ceilometer PoV.

    This reverts commit d17e75d2675c1acf09adc27249b1e968450c5229.

    Closes-bug: #1649921
    Change-Id: I63479d19fcf4a99fb198859c2e6ae370ff0e24e1
    (cherry picked from commit 72b5a1e2bc9f4fc3f551a41aa0e40cd59f8ab5c9)

tags: added: in-stable-mitaka
Revision history for this message
gordon chung (chungg) wrote :
Changed in ceilometer:
status: New → Fix Released
importance: Undecided → Medium
assignee: nobody → Mehdi Abaakouk (sileht)
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/ceilometer 6.1.4

This issue was fixed in the openstack/ceilometer 6.1.4 release.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/ceilometer 7.0.2

This issue was fixed in the openstack/ceilometer 7.0.2 release.

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.