Master going into backoff wrongly

Bug #1645974 reported by Hari Prasad Killi
8
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Juniper Openstack
Fix Committed
High
Naveen N

Bug Description

Initially when we have VM1 as master and VM2 as backup. Then, VRRP advertisements are lost, VM2 advertises itself as master and the toggling happens. It happens 5 times on VM2 and it goes into back off and waits for 10s. On VM1, the toggling has happened 4 times till now. Now after 10s, VM2 restarts ARP probe and toggles again. Upon this, VM1 is considering this as the fifth toggle (this is the bug) and starting a back off for 10s. After 10s, VM1 again becomes master.

Tags: vrouter
Revision history for this message
Hari Prasad Killi (haripk) wrote :
Changed in juniperopenstack:
status: New → Fix Committed
milestone: none → r4.0