SNMP polling timeout in UI incorrect

Bug #1487240 reported by Michael Langdon
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Juniper Openstack
Status tracked in Trunk
Trunk
Fix Committed
Medium
ted ghose

Bug Description

When configuring SNMP polling timeout via UI for physical devices, the UI says to enter value in seconds. System expects value to be delivered in msec. It seems the conversion to msec is not happening and the value is delivered to the config node as 5 msec. This is causing snmp to fail. Leaving field blank takes the default value (not sure what that is) and things seem to work ok.

Tags: analytics ui
Raj Reddy (rajreddy)
Changed in juniperopenstack:
milestone: none → r2.30-fcs
assignee: nobody → ted ghose (rintu)
importance: Undecided → Medium
Revision history for this message
OpenContrail Admin (ci-admin-f) wrote : [Review update] master

Review in progress for https://review.opencontrail.org/13356
Submitter: Raj Reddy (<email address hidden>)

Revision history for this message
OpenContrail Admin (ci-admin-f) wrote : A change has been merged

Reviewed: https://review.opencontrail.org/13356
Committed: http://github.org/Juniper/contrail-controller/commit/c8932d8c035c89c6880bd9817f2725655107927a
Submitter: Zuul
Branch: master

commit c8932d8c035c89c6880bd9817f2725655107927a
Author: Raj Reddy <email address hidden>
Date: Wed Aug 26 14:31:36 2015 -0700

netsnmp expects the Timeout in microsec, hence converting sec to usec before
passing to netsnmp

Change-Id: I011b1166e27c283bff061124a19e56097c66cf91
Closes-Bug: #1487240

Raj Reddy (rajreddy)
no longer affects: opencontrail
To post a comment you must log in.