nailgun::cobbler: bootstrap: adjust network configuration timeout

Bug #1485546 reported by OpenStack Infra
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Fuel for OpenStack
Confirmed
Medium
Fuel Documentation Team

Bug Description

https://review.openstack.org/213519
commit efe317702f911db5d04c9d2430c98ac4df9ff1c6
Author: Alexey Sheplyakov <email address hidden>
Date: Sun Aug 16 19:02:48 2015 +0300

    nailgun::cobbler: bootstrap: adjust network configuration timeout

    live-boot assumes 15 sec is enough to setup the network interface
    However some Ethernet cards might take (much) longer to initialize,
    which causes a boot failure. To solve the issue set the timeout to
    2 minutes by default, and make it configurable via the
    BOOTSTRAP/ethdevice_timeout knob in astute.yaml

    DocImpact: bootstrap configuration item: ethdevice_timeout
    Closes-Bug: #1485188
    Change-Id: I4ac18aa229f13a9283b9bb0b19f1ce36e43954da

Changed in fuel:
assignee: nobody → Fuel Documentation Team (fuel-docs)
Changed in fuel:
status: New → Confirmed
Mike Scherbakov (mihgen)
tags: added: docs
Changed in fuel:
importance: Undecided → Medium
importance: Medium → High
milestone: none → 7.0
Igor Shishkin (teran)
Changed in fuel:
milestone: 7.0 → 8.0
Dmitry Pyzhov (dpyzhov)
tags: added: area-docs
Changed in fuel:
importance: High → Medium