Value of 1umil incorrectly set to 10µmil
Bug #1413254 reported by
Peter S. May
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
pcb |
Fix Released
|
Medium
|
Bert Timmerman |
Bug Description
In the file /src/parse_y.y, the scale assigned to a value with the unit `umil` is specified as mil / 100000.0 (the correct value would be mil / 1000000.0).
Problem was noticed while I was studying the source; there are no steps to reproduce.
Changed in pcb: | |
assignee: | nobody → Bert Timmerman (bert-timmerman) |
status: | New → Fix Committed |
milestone: | none → next-bug-release |
importance: | Undecided → Medium |
Changed in geda-project: | |
importance: | Undecided → Medium |
status: | New → Fix Released |
Changed in pcb: | |
status: | Fix Committed → Fix Released |