The node power monitoring service does not check nodes in parallel
Bug #1370897 reported by
Julian Edwards
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
High
|
Blake Rouse |
Bug Description
This is stupidly slow even for the 5 nodes in my test rig. For large clusters, it will be unusable.
Related branches
lp:~blake-rouse/maas/power-query-multiple
- Gavin Panella (community): Approve
- Blake Rouse (community): Abstain
-
Diff: 232 lines (+98/-30)4 files modifiedsrc/provisioningserver/pserv_services/node_power_monitor_service.py (+4/-1)
src/provisioningserver/pserv_services/tests/test_node_power_monitor_service.py (+9/-2)
src/provisioningserver/rpc/power.py (+47/-24)
src/provisioningserver/rpc/tests/test_power.py (+38/-3)
Changed in maas: | |
status: | New → Triaged |
importance: | Undecided → High |
milestone: | none → 1.7.0 |
tags: | added: robustness |
tags: |
added: power removed: robustness |
Changed in maas: | |
status: | Triaged → In Progress |
Changed in maas: | |
status: | In Progress → Triaged |
Changed in maas: | |
milestone: | 1.7.0 → next |
Changed in maas: | |
status: | Triaged → Fix Committed |
Changed in maas: | |
milestone: | next → 1.7.1 |
Changed in maas: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
This was done so we don't hammer BMC's that control multiple nodes through one BMC, but we could do a few at a time even for a BMC with multiple nodes this probably wouldn't be a problem.