UI becomes unresponsive (unaccessible) if RPC to cluster fails
Bug #1360004 reported by
Andres Rodriguez
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
Critical
|
Gavin Panella |
Bug Description
==> maas-django.log <==
ERROR 2014-08-21 17:56:44,885 maasserver Unable to get RPC connection for cluster 'maas'
ERROR 2014-08-21 17:56:47,223 maasserver Unable to get RPC connection for cluster 'maas'
Seen that error and can't access the WebUI
Related branches
lp:~allenap/maas/reduce-wait-for-client
- Blake Rouse (community): Approve
-
Diff: 19 lines (+2/-2)1 file modifiedsrc/maasserver/rpc/__init__.py (+2/-2)
Changed in maas: | |
assignee: | nobody → Gavin Panella (allenap) |
summary: |
- UI becomes unresponsive (unaccessible) if RPC to cluster fails? + UI becomes unresponsive (unaccessible) if RPC to cluster fails |
Changed in maas: | |
milestone: | none → 1.7.0 |
Changed in maas: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
Seems to be the same problem I got when using the dev environment this morning.