Correct (flatten) Mixxx's baseline frequency response curve
Bug #1011092 reported by
Sean M. Pappalardo
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Mixxx |
Fix Released
|
Medium
|
Daniel Schürmann |
Bug Description
As discussed here: http://
Get Mixxx as close to completely flat frequency response as possible with all controls at unity and ReplayGain turned off. Specifically, make the HF roll-off dependent on output sampling rate, but higher than the Nyquist frequency in all cases (22kHz for 44.1kHz sampling rate, 24kHz for 48, 48 for 96, etc.)
Changed in mixxx: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
All new EQ types have a fully flat responds at unity.
However the Linkwizt-Riley type has a linear phase shift,
For bit perfect at unity use the Bessel-LV type.
So this one should be fixed now.
Please reopen it if there is still an issue.