Management interface may not be reachable when the underlying network MTU is less than 1500.

Bug #1539786 reported by Mark McClain
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Astara
Fix Released
Critical
Mark McClain

Bug Description

When the physical network MTU is 1500 and overlays are in use, connectivity to management interface may not work. The appliance should be made to support variable MTUs for interfaces.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to astara-appliance (master)

Fix proposed to branch: master
Review: https://review.openstack.org/274281

Changed in astara:
status: Confirmed → In Progress
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to astara (master)

Fix proposed to branch: master
Review: https://review.openstack.org/274293

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to astara-appliance (master)

Reviewed: https://review.openstack.org/274281
Committed: https://git.openstack.org/cgit/openstack/astara-appliance/commit/?id=6eccab929bbb520689b5d949694be2a83cee77cf
Submitter: Jenkins
Branch: master

commit 6eccab929bbb520689b5d949694be2a83cee77cf
Author: Mark McClain <email address hidden>
Date: Fri Jan 29 16:52:25 2016 -0500

    Make the management interface MTU configurable

    The default MTU for the management interface is sometimes bigger than
    allowable by the physical infrastructure. Make the MTU configurable in
    cloud-init and via config json. For cloud-init default it to the minimum size
    for IPv6 if the value is not specified in boot command.

    Change-Id: Ib4d4381f6977aabbeefd2f520bb5fc26ea54ffcd
    Closes-Bug: #1539786

Changed in astara:
status: In Progress → Fix Released
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to astara (master)

Reviewed: https://review.openstack.org/274293
Committed: https://git.openstack.org/cgit/openstack/astara/commit/?id=b236be83fc3918e8b509707db91d12f9321faaf5
Submitter: Jenkins
Branch: master

commit b236be83fc3918e8b509707db91d12f9321faaf5
Author: Mark McClain <email address hidden>
Date: Fri Jan 29 18:43:19 2016 -0500

    Add variable MTU support to the orchestrator.

    This change add variable MTU support for each interface if the
    underlying Neutron cloud supports it.

    Change-Id: I52b2d95e892440afa7b941239abd44d37fc224a0
    Depends-On: Ib4d4381f6977aabbeefd2f520bb5fc26ea54ffcd
    Closes-Bug: #1539786